ABB ACS880 Firmware Manual page 390

Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

390 Parameters
No.
Name / Range /
Selection
True
RO1
Other [bit]
33.14
On-time 1 warn
message
On-time 1 exceeded
Clean device
Maintain additional
cooling fan
Maintain cabinet fan
Maintain DC
capacitors
Maintain motor
bearing
33.20
On-time 2 actual
0...4294967295 s
33.21
On-time 2 warn limit
0...4294967295 s
33.22
On-time 2 function
b0
Counter mode
b1
Warning enable
b2...15
Reserved
0000h...FFFFh
33.23
On-time 2 source
False
Description
Constant 1.
Bit 0 of
10.21 RO status (page
See
Terms and abbreviations (page
Selects the optional warning message for on-time timer
1.
A886 On-Time
1. The message text can be edited on
the control panel by choosing Menu – Settings – Edit
texts.
A88C Device
clean.
A890 Additional cooling
A88E Cabinet
fan.
A88D DC
capacitor.
A880 Motor
bearing.
Displays the actual present value of on-time timer 2.
The timer runs whenever the signal selected by
parameter
33.23 On-time 2 source
When the timer exceeds the limit set by
2 warn
limit, bit 1 of
33.1 Counter status
warning specified by
33.24 On-time 2 warn message
also given if enabled by
The timer can be reset from the Drive Composer PC
tool, or from the control panel by keeping Reset
depressed for over 3 seconds.
Actual present value of on-time timer 2.
Sets the warning limit for on-time timer 2.
Warning limit for on-time timer 2.
Configures on-time timer 2.
0 = Loop: When the limit is reached, the counter is reset.
The counter status (bit 1 of 33.1) switches to 1 for one
second. The warning (if enabled) stays active for at
least 10 seconds.
1 = Saturate: When the limit is reached, the counter
status (bit 1 of 33.1) switches to 1, and remains so until
33.20
is reset. The warning (if enabled) also stays active
until
33.20
is reset.
0 = Disable: No warning is given when the limit is
reached
1 = Enable: A warning (see 33.24) is given when the limit
is reached
Selects the signal to be monitored by on-time timer 2.
Constant 0 (timer disabled).
214).
169).
fan.
is on.
33.21 On-time
is set to 1. The
33.22 On-time 2
function.
Def / Type
FbEq 16b / 32b
1
2
On-time 1 exceeded
/ uint32
0
6
7
8
9
10
- / uint32
is
- / -
- / uint32
- / -
- / uint16
1 = 1
False / uint32
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents