No.
Name / Range /
Selection
11.59
Freq out 1 src max
-32768.000 ...
32767.000
11.60
Freq out 1 at src min
0...16000 Hz
11.61
Freq out 1 at src max
0...16000 Hz
11.81
DIO filter time
0.3 ... 100.0 ms
Description
Defines the real value of the signal (selected by
parameter
11.55 Freq out 1 source
parameter
11.54 Freq out 1 actual
corresponds to the maximum value of frequency output
1 (defined by parameter
See parameter
11.58 Freq out 1 src
Real signal value corresponding to maximum value of
frequency output 1.
Defines the minimum value of frequency output 1. See
diagrams at parameter
Minimum value of frequency output 1.
Defines the maximum value of frequency output 1. See
diagrams at parameter
Maximum value of frequency output 1.
Defines a filtering time for parameter
and
11.2 DIO delayed
status. The filtering time will only
affect the DIOs that are in input mode.
Filtering time for 11.1.
and shown by
value) that
11.61 Freq out 1 at src
min.
11.58 Freq out 1 src
min.
11.58 Freq out 1 src
min.
11.1 DIO status
Parameters 223
Def / Type
FbEq 16b / 32b
1500.000; 1800.000
(95.20 b0) / real32
max).
1 = 1 / 1000 = 1
0 Hz / real32
1 = 1 Hz / 1 = 1 Hz
16000 Hz / real32
1 = 1 Hz / 1 = 1 Hz
10.0 ms / uint32
10 = 1 ms / 10 = 1 ms