Fig. 37
1. Ignition housing
Step
4
Install ignition housing on the crankcase
with puller assy. part no. 876010.
Fig. 38
1. Ignition housing
WARNUNG WARNING
Danger of injury!
The magnet of the fly wheel pulls the ignition co-
ver towards the engine/sealing surface with
great force.
Fingers can be crushed.
Effectivity: 912 i Series
Edition 1/Rev. 1
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
Step
5
Turn the water pump wheel slightly so that
the gear wheels can mesh.
6
Fasten the ignition housing to the crank-
case using Allen screws.
Tightening torque 10 Nm (88.48 in. lb.)
NOTICE
WARNUNG
The ignition housing must be attached manually
without tapping.
Fig. 39
Ignition housing screw diagram
1. M6x30 Allen screws
3. Ignition housing assy.
Step
7
Secure M6x50 Allen screw with LOCTITE
243 and tighten it.
Tightening torque 10 Nm (88.48 in. lb.)
NOTICE
WARNUNG
Do not use a longer screw!
The screw would press on the cylinder shroud
and cause damage to piston and cylinder.
Procedure
2. M6x50 Allen screws
Procedure
24-20-00
Page 18