INSTALLATION
ELECTRIC STARTER - INSTALLATION
Preparation
- Check that the o-rings are securely fitted on
the bearing flange.
- Lightly grease the o-ring on the bearing
flange and the centring bore in the ignition
housing with KLUEBER ISOFLEX TOPAS
Nb5051.
NOTICE
WARNUNG
Ensure that the electric starter is in the correct
installation position. See
Step
1
Push the whole electric starter into the
ignition housing.
2
Tighten the M5 hex. nuts equally.
Tightening torque 6 Nm (53.09 in. lb.).
3
Connect the positive pole on the electric
starter.
Fig. 4
1. Electric starter
3. M5 hex. screw
5. M5 hex. nut
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Fig.
4.
Procedure
2. Ignition housing
4. O-Ring
Fig. 5
1. Positive (+) cable
3. Washer
FINISHING WORK
- Connect the negative terminal of the on-
board battery.
- Carry out an engine test run. See relevant
Maintenance Manual Line for the 912 i Series
engine type.
2. Hex. screw