Check of the Software version
Step
1
After the Software flashing process has
finished, the "Connection"-Tab will be
shown. Check if the Software P/N equals
the Softwareversion which was intended
to be installed.
2
Change to section "Diagnostic" Mode.
3
A window will open to inform the user that
a reboot of the ECU is required when
changig from "Maintenance" to "Diagnos-
tic"-Mode. Confirm the information with
"OK".
4
Reboot the ECU by turning the "Master
Switch" or the "LANE A", "LANE B"
Switches to "OFF" and "ON" again.
5
Check warning lamp indicators. If both
warning lamp indicators (section "LANE
Health"/top toolbar) start to flash "RED"
after rebooting the ECU, check compati-
bility between set Engine type and ECU
Softwareversion.
6
Change to "Health"-Tab and check the
Sensor Status and Device Status. If there
are Errors/Events the ECU might be dam-
aged and further investigation needs to be
done.
7
The Software flashing process itself is
now complete. Turn the "Master" Switch",
the "Battery Backup"-Switch and the
"LANE A/B" Switches back to "OFF".
8
Remove all wiring connections.
Effectivity: 912 i Series
Edition 1/Rev. 1
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
FINISHING WORK
- Attach all the necessary fastenings (e.g.
cable ties, holders, clamps etc.) of the wiring
harness.
- Transfer the actual data documented when
removing the old ECU to the newly installed
ECU.
- Delete the error memory of the new ECU.
- Carry out an engine test run. See section 70-
00-00.
- Read out the ECU.