Step
3
Carefully pull EGT 1 and EGT 2 (cylinders
1 and 2) out of the locking plate.
4
Press the metal bracket and unplug the
connectors.
Fig. 4
1. EGT connector
Step
5
Loosen M5x16 Allen screws with A5 lock
washers.
Fig. 5
1. M5x16 Allen screw
3. Cable holder
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
2. Connector
Procedure
2. A5 lock washer
Step
6
Unplug the connectors to the double igni-
tion coils.
7
Remove the double ignition coils
Fig. 6
1. Double ignition coils
RESISTANCE SPARK PLUG CONNEC-
TOR AND IGNITION CABLE ASSY. -
REMOVAL
See
Fig. 7
and
Fig. 8
Step
1
Remove cable ties.
2
Unplug the resistance spark plug connec-
tor.
3
Unplug ignition cable from ignition coils
and remove it.
NOTE:
If this proves difficult, push down
with a hex. socket wrench or
similar.
Do not use a sharp tool!
Procedure
2. Ignition coil connector
(coil 1, coil 2, coil 3, coil 4)
Procedure
74-20-00
Page 9
July 01/2012