Rotax 912 i Series Maintenance Manual page 249

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

- For removal and installation of pressure and
temperature sensors, see section 76-70-00
Sensors and actuators.
NOTE: The pressure and temperature sensors
must only be removed if absolutely ne-
cessary!
Fig. 26
1. Airbox
3. Pressure sensors
AIRBOX - REMOVAL
Step
1
Loosen the M6 hex. nut attaching the air-
box to the ignition housing along with the
washer.
Fig. 27
1. M6 hex. nut
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
2. Temperature sensor
Procedure
2. 6.4 washer
Step
2
Remove the two 1-ear clamps.
3
Remove the airbox.
Fig. 28
1. 1-ear clamps
NOTE: Remove the nipple and M6x12 hex.
screw only if absolutely necessary!
See
Fig. 29
Step
4
Loosen the nipple and M6x12 hex. screw
along with the gasket ring.
Fig. 29
1. Nipple
3. M6x12 hex. screw
Procedure
2. Connecting piece
Procedure
2. Gasket ring
73-10-00
Page 17
July 01/2012