PRESSURE SENSOR (MAPS_1, MAPS_2) - INSPECTION
Signal
Supply voltage
OUT
GROUND
Measurement
Current
Pressure (bar/psi)
[in V]
2 bar / 29 psi
4.5 V
0
0 V
PRESSURE SENSOR (OPS) - INSPECTION
Signal
Supply voltage
OUT
GROUND
Measurement
Current
Pressure (bar/psi)
10 bar / 145 psi
4.5 V
0
0 V
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Pressure sensor (MAPS_1, MAPS_2)
PIN
B
C
A
06345
Pressure sensor (OPS)
PIN
B
C
A
[in V]
06345
Voltage [in V]
5 V ± 0.5
0.5 .... 4.5 V
0 V
A
A B
B
C
C
Voltage [in V]
5 V ± 0.5
0.5 .... 4.5 V
0 V
A
A B
B
C
C
Remarks
corresponds to 0 to 2 bar
5V
06353
Remarks
corresponds to 0 to 10 bar
5V
06353