that all the parts can be laid out and allocated
according to their installation position.
Step
1
Remove the circlip from the sprag clutch
housing.
2
Compress the Seeger ring slightly using
Seeger ring pliers and take the sprag clut-
ch out of the sprag clutch housing while
turning it.
Fig. 6
1. Circlip
3. Sprag clutch housing
Fig. 7
1. Sprag clutch housing
3. Circlip
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINENANCE MANUAL
Procedure
2. Seeger ring
2. Sprag clutch
INSPECTION
SPRAG CLUTCH HOUSING
SINGLE PARTS CHECK
Preparation
- Clean all parts carefully. See also section 05-
00-00 "Procedures"
SPRAG CLUTCH HOUSING CHECK
Step
1
Check whether oil sludge has accumu-
lated in the sprag clutch housing.
2
Check that the oil nozzle for the generator
is clear.
NOTE:
The nozzle is 0.8 mm in diame-
ter. Check using a 0.5 mm wire.
3
Check crankshaft bore.
4
Check the cone surface.
5
Check the sprag clutch engagement
faces in the sprag clutch housing.
NOTICE
WARNUNG
If the oil nozzle is clogged, the generator coils
are no longer cooled sufficiently.
Fig. 8
1. Oil nozzle
3. Sprag clutch engagement face
Procedure
2. Cone surface
72-20-00