Rotax 912 i Series Maintenance Manual page 301

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

WEAR LIMITS
Description
Water pump
Reference to
WP01 8.55 mm
flat surface
Distance from impel-
WP02 0.3 mm
ler
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Current measurement
value
min
max
8.85 mm
0.3366 in.
0.3484 in.
0.5 mm
0.012 in.
0.020 in.
Tolerance
Tolerance
limit
limit
100 %
50 %
8.85 mm
0.3484 in.
0.7 mm
0.6 mm
0.028 in.
0.024 in.
Measu-
rements
current
replaced
current
replaced
75-00-00
Page 13
July 01/2012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

912 is912 isc

Table of Contents