TEMPERATURE SENSOR (OTS) - INSTAL-
LATION
Step
1
Clean the thread of the temperature sen-
sor.
2
Lubricate the thread of the pressure sen-
sor with LOCTITE 243 and use an SW 19
open-ended spanner part no. 876130 (or
a similar tool) to tighten it.
Tightening torque 15 Nm (88.48 in. lb.).
3
Plug the respective wiring harness con-
nector into the corresponding tempera-
ture sensor. See section 76-50-00.
Fig. 29
1. Temperature sensor (OTS)
Step
4
Attach cable ties.
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
Procedure
Fig. 30
1. Temperature sensor (OTS)
TEMPERATURE SENSOR (EGT1/EGT2/
EGT3/EGT4) INSTALLATION
Step
1
Clean the thread of the temperature sen-
sor.
2
Lubricate thread of temperature sensor
with LOCTITE ANTI SEIZE.
Fig. 31
1. Temperature sensor
2. Cable ties
Procedure
2. Inlet pipe
76-70-00
Page 26
July 01/2012