Fig. 15
1. Ignition cable assy.
DOUBLE IGNITION COIL - INSTALLATION
The double ignition coil is installed and removed
in the same way. The following should be noted.
The red cable is positive (+), the red
NOTE:
cable with the black dash is negative (-).
Double ignition coils are labelled + and -!
Step
1
Plug in the double ignition coil connectors.
Fig. 16
1. Double ignition coils
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
2. Cable ties
Procedure
2. Ignition coil connector
(coil 1, coil 2, coil 3, coil 4)
Step
2
Fix the double ignition coils with M5x16
Allen screws with plug holders and A5
lock washers.
Tightening torque 5 Nm (44.25 in. lb.).
Fig. 17
1. M5x16 Allen screw
3. Plug holder
Step
3
Plug in the connector to the EGT connec-
tor.
NOTE:
Compress the connector with
the EGT connector so that the
spring clip latches in.
Fig. 18
1. EGT connector
Procedure
2. A5 lock washer
Procedure
2. Connector
74-20-00
Page 15