Rotax 912 i Series Maintenance Manual page 355

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

Fig. 1
1. Starter relay
3. 6.4 washer
5. Grounding
AMBIENT PRESSURE SENSOR - DIS-
CONNECTION
Wiring harness designation:
- AAPTS
Step
1
Push in the tab on the top of the connector
and at the same time pull the connector
out of the connection socket.
Fig. 2
1. Tab
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
2. M6 hex. nut
4. Faston connector
6. Allen screw
Procedure
2. Connection socket
FUSE BOX (FUSE BOX) - DISCONNEC-
TION
- See also section 76-10-00 Fuse box.
Step
1
Loosen M5 hex. nut from the earthing
cable on controller A.
Fig. 3
1. Fusebox
3. Controller connector A
5. Controller connector B
Fig. 4
1. Earthing cable
3. Controller connector A
Procedure
2. Controller LANE A
4. Controller LANE B
6. Earthing cable harness
2. Controller LANE A
76-50-00
Page 7
July 01/2012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

912 is912 isc