Step
7
Wait until connection state lights are
"RED"
8
Connect power adapter with power sup-
ply.
9
The connection state (bottom-right corner
of B.U.D.S.) for both LANES should turn
"RED" to "ORANGE" and finally to
"GREEN".
Fig. 12
B.U.D.S. Aircraft "Maintenance Mode" (connect)
NOTICE
WARNUNG
If connection status lamps would not turn to
"GREEN", try to disconnect and reconnect the
power adapter.
Step
10
When both connection state indicators
become "GREEN", change to "Logs" Tab.
11
Click on "Extract Logs". A settings window
named "ECU Log Extraction" should
open.
Effectivity: 912 i Series
Edition 1/Rev. 1
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
09963
Procedure
Fig. 13
„B.U.D.S. Aircraft „Maintenance Mode" : Logs
Step
12
In this window ("ECU Log Extraction")
choose "LANE A and LANE B" for Log-ex-
traction (field:"ECU LANE Selection").
NOTE:
If only one LANE has been con-
nected or the user wants to ex-
tract the logs from one LANE,
the corresponding option must
be selected here.
13
In the field "ECU Log Selection" the type
of extracting Logs must be chosen.
Choose "Fault and Data logs".
Faultlogs: Fault/Failure/Warning en-
NOTE:
tries in the ECU.
Datalogs: ECU information stored in
a circular buffer.
Step
14
Furthermore select ECU Log Extraction
Directory.
NOTICE: The User must have writing per-
mission for this folder.
15
Press "OK" subsequently. The extraction
process will start.