Check of the Software version
WARNUNG WARNING
Do not disconnect or power down the ECU du-
ring the software flashing process.
If the Software flashing process was
NOTE:
interrupted (e.g. the ECU was discon-
nected from the computer) it is neces-
sary to restart the flashing process
with the desired Software. If this flash-
ing process also fails, flash the initial
software on the ECU and afterwards
retry flashing the desired Software-
version.
Step
1
Change to "Diagnostic".
2
A window will open to inform the user that
a reboot of the ECU is required when
changing from "Maintenance Mode" to
„Diagnostic Mode". Confirm this window
with "OK".
3
Disconnect and reconnect the power sup-
ply.
4
Change to "Health"-Tab and check if the
Sensor Status and Device Status is equal
the Sensor Status and Device Status in
following
Fig.
Errors/Events the ECU might be dam-
aged and further investigation needs to be
done.
Effectivity: 912 i Series
Edition 1/Rev. 1
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
29. If there are additional
Fig. 29
B.U.D.S. Aircraft „Diagnostic Mode" Health (Service
Wiring Harness)
Step
5
The Software flashing process itself is
now complete. First of all the power sup-
ply needs to be disconnected.
6
Disconnect the Service Wiring Harness
from the ECU.
7
All cable can be disconnected.
09968
Procedure
76-10-00
Page 23