Rotax 912 i Series Maintenance Manual page 380

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

Step
3
Unscrew the temperature sensor with an
SW 19 open-ended spanner part no.
876130 (or similar tool) and remove it to-
gether with the sealing ring.
4
Close the threaded bore with the appro-
priate protective covering.
Fig. 7
1. Temperature sensor
TEMPERATURE SENSOR (EGT1/EGT2/
EGT3/EGT/4) - REMOVAL
Installation position: Exhaust pipes
Step
1
Carefully pull temperature sensor (EGT)
out of the locking plate.
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
2. Sealing ring
Procedure
Fig. 8
1. Temperature sensor (EGT)
Step
2
Remove the respective wiring harness
plug from the corresponding temperature
sensor (EGT1/EGT2/EGT3/EGT4). See
also section 76-50-00 Wiring harness
(main strand).
3
Press the metal bracket and separate the
connectors.
Fig. 9
1. Temperature sensor
Step
4
Use a size 17 open-ended spanner (or
similar tool) to detach the temperature
sensor from the exhaust pipe.
2. Locking plate