Rotax 912 i Series Maintenance Manual page 248

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

Fig. 23
1. Outer screw-fastening
Step
4
Remove the insulating flange of the cylin-
der heads.
5
Close the intake duct using a plug (part
no. 860397).
NOTICE
WARNUNG
Close the intake duct immediately so that no
debris particles can get into the combustion
chamber!
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
2. Inner screw-fastening
Procedure
Fig. 24
1. Insulating flange
Fig. 25
1. Plug part no. 860397
RIGHT-HAND 1/3 INTAKE MANIFOLD -
REMOVAL
- It is removed in the same way as the left-hand
2/4 intake manifold.
PRESSURE AND TEMPERATURE SEN-
SOR - REMOVAL
Preparation
See
Fig. 26
- Unplug the connectors of the 2 pressure sen-
sors and 2 temperature sensors. See also
section 76-50-00 Wiring harness.
- Loosen and detach the wiring harness (main
strand) from all fastenings (cable ties,
retaining fixtures) on the engine. See also
section 76-50-00 Wiring harness.
73-10-00
Page 16
July 01/2012