Fig. 12
1. Lock
EGT CONNECTOR AND IGNITION COIL -
DISCONNECTION
See also section 74-20-00 Ignition unit.
Wiring harness designation:
- EGT_1, EGT_2
- EGT_3, EGT_4
- COIL_1
- COIL_2
- COIL_3
- COIL_4
Step
1
Remove the cable clamps of the wiring
harness on the intake manifold.
NOTICE
WARNUNG
The Allen screws go into the intake duct. The
Allen screws are therefore secured with LOCTI-
TE 243. Leaking Allen screws can cause an ex-
cessively lean mixture!
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
Fig. 13
1. M6x14 Allen screw
3. 12/M6 cable clamp
Step
2
Pull out 4 ignition coil connectors from
each side.
Use a suitable tool to pull out
NOTE:
the ignition coil plugs.
Fig. 14
1. Ignition coil connector
3. EGT connector
Step
3
Carefully pull EGT_1 and EGT_2 (cy-
linder 1 and 2) out of the locking plate.
4
Press the metal bracket and separate the
connectors.
2. 6.4 washer
Procedure
2. Double ignition coils
Procedure
76-50-00
Page 10
July 01/2012