Rotax 912 i Series Maintenance Manual page 333

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

Software flashing process with B.U.D.S. Aircraft
Step
1
Open B.U.D.S. Aircraft Software.
2
Open the "Preferences" Window and
make sure that a Baud Rate of 500 kbs is
selected (Field: Maintenance "Mode").
Fig. 24
B.U.D.S. Aircraft "Preferences"
Step
3
Closed the window "Preferences" with
„OK".
4
Change to "Maintenance Mode" Tab.
Fig. 25
B.U.D.S. Aircraft "Maintenance Mode"
Effectivity: 912 i Series
Edition 1/Rev. 1
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
09962
Procedure
09961
If the ECU at this time is supplied with
NOTE:
power, a restart is required.
Step
5
Wait until the Connection State Indicators
(Bottom-Right) turn to RED.
6
Now connect the power supply with the
line voltage.
7
Wait until the Connection State Indicators
turn to "GREEN" and the fields in the
„"Connection"-Tab (ECU Configuration
Data and User Configurable Parameters)
fill with data.
If connection status lamps do not turn
NOTE:
to GREEN, try to disconnect and re-
connect the power adapter.
Fig. 26
B.U.D.S. Aircraft "Maintenance Mode"
Step
8
Check the currently installed ECU Soft-
wareversion and the set Engine type.
Procedure
09963
Procedure
76-10-00
Page 21
October 01/2013