Rotax 912 i Series Maintenance Manual page 338

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

The currently installed ECU Software
NOTE:
version ("Software P/N"/section "
ECU Configuration Data") and the set
Engine Type (section "User Configu-
rable Parameters") can be seen in the
"Connection" Tab. The last three dig-
its of the "Software P/N" illustrate the
currently installed ECU Software ver-
sion.
WARNUNG WARNING
Only Software that is suits a specific engine type
is allowed to be flashed on an ECU (see
SB-912 i-002iS). If the set Engine Type set in
the ECU deviates from the hardware configua-
ration of the engine, contact a ROTAX Distribu-
tor immediately.
Step
11
Switch to "Software Load"-Tab.
12
Select "Browse" in the "Software Package
Loading" section.
13
Navigate to the appropriate ECU Soft-
ware file. (ath) and confirm with "Open".
14
The path to this file and the Software P/N
will be shown in the "Software Package
Loading" section.
Fig. 34
B.U.D.S. Aircraft Maintenance Load": Software Load"
Effectivity: 912 i Series
Edition 1/Rev. 1
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
09966
Step
15
Select "Load Package".
16
Consequently a window will open to en-
sure that the user is aware of flashing the
ECU Software. Confirm this window with
"OK".
17
Wait until the Software flashing process is
finished. The process itsself should take
approximately 1 minute (a status display
will indicate the progress).
WARNUNG WARNING
Do not disconnect or power down the ECU du-
ring the Software flashing process.
If the Software flashing process was
NOTE:
interrupted (e.g. the ECU was discon-
nected from the computer) it is neces-
sary to restart the flashing process
with the desired Software. If this flash-
ing process also fails, flash the initial
software on the ECU and afterwards
retry flashing the desired Software-
version