Fig. 30
1. Filler plug
3. Connector receptacle
5. Cable sleeves
Step
4
Install the lock
At malfunctions such as wire breakage
NOTE:
and faulty plugs, the particular damage
can be repaired.
Cable must be long enough when plug is
removed.
Repair of malfunctions with the tools
mentioned here must conform to the air-
craft standards of the respective country.
Part no. of connector set
866420
866422
Effectivity: 912 i Series
Edition 1/Rev. 1
BRP-Powertrain
MAINTENANCE MANUAL
2. Insulator (rubber)
4. Marks
6. Latch
Procedure
DEUTSCH HDT- 48 - 00
Fig. 31
1. Lock
Step
5
Install 8/M6 cable clamps.
NOTE:
The bends of the cable clamps
must be installed in a diametri-
cally opposed manner.
6
Adjust cables. Tighten M6x20 Allen
screw.
Tightening torque 10 Nm (88.48 in. lb.).
Fig. 32
1. M6x20 Allen screw
Corresponding tool
Procedure
2. Cable clamp 8/M6
24-20-00
Page 16
October 01/2013