Rotax 912 i Series Maintenance Manual page 56

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

REMOVAL
Preparation
NOTICE
WARNUNG
Use appropriate protective coverings to prevent
the ingress of foreign bodies into all discon-
nected lines and connections.
- Drain coolant. See relevant Maintenance
Manual Line for the 912 i Series engine type.
- Remove adjacent assemblies (electric starter,
water pump).
- Remove coolant hoses from cylinder head.
- Remove rev counter assy. To do this, see
section 76-70-00 Sensors and actuators.
The assemblies and lines are only to be
NOTE:
removed if necessary and only as far as
is necessary!
IGNITION HOUSING - REMOVAL
Step
1
Detach the electrical connection to the
stator by disconnecting the controller con-
nector. Mark before detaching!
2
Press on the catch and disconnect the
connector.
Fig. 1
1. Controller connector
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
2. Connection socket
Step
3
Loosen the airbox bracket. Loosen the
hex. nut and remove it along with the
washer.
Fig. 2
1. Washer A 6.4
3. Rubber buffer 20x10xM6
Push airbox upwards and wedge in
NOTE:
place.
Step
4
Loosen 2 Allen screws M5x45 and
hex. nuts M5 on electric starter.
Fig. 3
1. M5x45 Allen screw
3. OPS pressure sensor (oil)
Step
5
Loosen 5 M6x30 and 2 M6x50 Allen
screws with washers 6.4.
6
Disconnect OPS pressure sensor.
Procedure
2. M6 hex. nut
Procedure
2. M5 hex. nut
Procedure
24-20-00
Page 6
July 01/2012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

912 is912 isc

Table of Contents