Rotax 912 i Series Maintenance Manual page 395

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

PRESSURE/TEMPERATURE SENSOR
(AAPTS) - INSTALLATION
Step
1
Follow the aircraft manufacturer's instruc-
tions for assembly.
2
Plug the respective wiring harness con-
nector into the corresponding pressure or
temperature sensor.
See section 76-50-00.
TEMPERATURE SENSOR (CTS) - INSTAL-
LATION
Step
1
Clean the thread of the temperature sen-
sor.
2
Lubricate the thread of the pressure sen-
sor with LOCTITE 243 and use an SW 19
open-ended spanner part no. 876130 (or
a similar tool) to tighten it.
Tightening torque 15 Nm (88.48 in. lb.).
3
Plug the respective wiring harness con-
nector into the corresponding tempera-
ture sensor. See section 76-50-00.
Fig. 26
1. Temperature sensor (CTS)
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
Procedure
TEMPERATURE SENSOR (MATS) - INS-
TALLATION
Step
1
Clean the thread of the temperature sen-
sor.
2
Fasten the temperature sensor and seal-
ing ring with an SW 19 open-ended span-
ner part no. 876130 (or similar tool).
Tightening torque 15 Nm (88.48 in. lb.).
Fig. 27
1. Temperature sensor (MATS)
Step
3
Plug the respective wiring harness con-
nector into the corresponding tempera-
ture sensor. See section 76-50-00.
4
Attach cable ties (strain relief).
Fig. 28
1. Temperature sensor (MATS)
Procedure
2. Sealing ring
Procedure
2. Cable ties
76-70-00
Page 25
July 01/2012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

912 is912 isc

Table of Contents