INSPECTION
PROPELLER GEARBOX
SINGLE PARTS CHECK
Preparation
- Clean all parts carefully.
GEAR COVER ASSY. CHECK
Step
1
Inspect the gear cover for cracks using a
dye penetrant method or magnetic parti-
cle method.
NOTE:
Only carry out in the case of
ground contact!
2
Inspect gear cover for damage.
-
Depressions and scratches outside
flat and sealing surfaces up to a
maximum of 0.5 mm in depth and 2
mm in diameter are permissible.
-
Traces of corrosion and pitting outside
sealing surfaces up to a maximum of
0.3 mm in depth and 2 mm in diame-
ter are permissible.
3
Inspect contact surfaces for Allen screws.
-
Indentations up to a maximum of 0.2
mm are permissible.
-
Bumps up to a maximum of 0.2 mm
are permissible.
Fig. 10
1. Flat sealing surfaces
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Procedure
2. Contact surfaces
Step
4
Inspect that the bearing bushing for sup-
porting the crankshaft in the gear cover is
secure and measure dimension (GB01).
See also section 72-10-00 Wear limits.
Fig. 11
1. Bearing bushing
PROPELLER SHAFT - INSPECTION
NOTICE
WARNUNG
The entire propeller shaft including fastening
bores must be free from corrosion; there must
be no fretting corrosion at the bearing points
either.
Step
1
Measure both bearing points. See also
section 72-10-00 Wear limits.
2
Roll the propeller shaft and check for run-
out. Check the axial runout of the propel-
ler flange. See section
72-10-00 Wear limits.
3
Check the oil seal running surface.
Procedure
Procedure
72-10-00
Page 10
July 01/2012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

912 is912 isc