Fig. 39
1. Ignition coil connector
3. EGT Connector
Step
4
Align the cables, they must not be stret-
ched.
5
Secure the cable clamp with an M6x14
Allen screw and 6.4 washer with LOCTI-
TE 243 and tighten it.
Tightening torque 10 Nm (88.48 in. lb.).
Fig. 40
1. M6x14 Allen screw
3. 12/M6 cable clamp
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
2. Double ignition coils
Procedure
2. 6.4 washer
NOTICE
WARNUNG
The Allen screws for the spring type hose clips
go into the intake duct, they are therefore glued
in with LOCTITE 243.
Leaking Allen screws can cause an excessively
lean mixture!
STRAIN RELIEF - CONNECTION
Step
1
Attach strain reliefs to the wiring harness
with cable ties.
Fig. 41
1. Plug holder
3. 142x3.2 mm cable tie
Procedure
2. 203x7.6 mm cable tie
76-50-00
Page 21
July 01/2012