Canon imageRUNNER ADVANCE C5500 Series Service Manual page 68

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

■ Detection when Feeding
● Detection in the Feed Direction
The original size in the feed direction is calculated using the detection signals of the Post-separation Sensor (PS_R1) and Lead
Sensor 1 (PS_A6).
PS_A6
● Detection in the Width Direction
The size is determined by the Original Size Sensor (UN_BO6).
■ Original Detection Control
Detection of originals in the Document Pickup Tray is performed by the Original Sensor (PS_N1).
When an original is placed in the Document Pickup Tray, the Detection Lever operates with the Lightproof Plate and the Lightproof
Plate passes through the Photo Interrupter. This makes the Original Sensor (PS_N1) emit an original detection signal (EMP_S).
If the Cover Open/Closed Sensor (PS_A5) detects that the Feeder Cover has been closed, a Feeder Cover open/close detection
signal (COVER_S) is emitted.
When the ADF Driver PCB receives a Feeder Cover open/close detection signal (COVER_S) and original detection signal (EMP_
S), an original set indication signal (EMP_LED) is sent to light the Original Set Display LED (LED).
ADF Driver PCB
PS_R1
UN_BO6
ADF Driver PCB