Startup Sequence

Power Supply Switch ON
Standby screen display
NOTE:
To achieve faster startup, the progress bar and the active PCB are not synchronized.
For this reason, the progress bar cannot be utilized for troubleshooting.
See the following error code list for the troubleshooting.
Related Error Code
• E602-0001: HDD detection error
HDD failed to be Ready. When the HDD is not formatted
When an HDD for another machine is connected at installation of the Removable HDD Kit
• E614-0001: Flash PCB detection error
Failed to recognize the Flash PCB. When the Flash PCB is not formatted
• E614-0002: Error in file system on the Flash PCB
The file system could not be initialized normally at startup.
• E614-4001: Error in file system on the Flash PCB
The OS boot file was not found.
• E614-4002: Error in file system on the Flash PCB
The OS kernel was not found.
• E748-2010: Flash PCB error / HDD error
When IPL (boot program) was not found, or the HDD could not be recognized
NOTE:
When the following errors occur, the system of the host machine has not been started normally. Therefore the error code is not
recorded in the log.
E602-XX01, E614-XX01
Name in bracket [ ]: Location where program is stored
• Initializing process of hardware
• Starting BIOS
[Main Controller PCB]
• Starting IPL (boot program) and OS system software
[Flash PCB]
• Starting application
[Hard disk]