End of the Call
The minimum length of the busy signal specifies the time (in seconds) the
PBX takes to identify a busy signal sequence. This prevents, for example,
the PBX identifying speech as a busy signal.
Tonalité continue
Requirements:
•
The PBX must recognise the continuous tone sent by the network
provider as the end of the call
The PBX recognises the continuous tone sent by the network provider as
the end of the call connection.
Évaluation du courant de boucle
Requirements:
•
The PBX must recognise the drop in loop current sent by the network
provider at the end of the call
The PBX recognises the end of the call when the network provider drops
the loop current to zero.
Chiffre MFV « D »
Requirements:
•
The PBX must recognise the DTMF code "D" sent by the network
provider at the end of the call.
The PBX recognises the end of the call when the network provider sends
DTMF code "D".
COMpact 5200/5200R/5500R - Firmware V7.4A - Advanced Information V08 06/2019