General Info
Note: After the port settings once have been made correctly, no further
changes should be made.
Source suitable for clock synchronisation
This port is used as source for the clock synchronisation and serves as
clock master for the PBX. Thus, interfering noise during calls are avoided.
Note: Select a port a source that is synchronous to the ISDN
exchange line.
Conserver la couche 1 active de manière permanente
Requirements:
•
External S
0
Constructions)
An activation of the layer 1 is requested from the PBX as soon as the
layer is put into the idle state by the network provider. Thus, for example,
a delay time is avoided before the external dial tone indicates its action
readiness.
Temporisation de la langue si Setup-Ack avec Inband Info
Interfering noise during dialling phase are avoided.
Always send DTMF digit after inband info
Note: This is a country-specific setting (only relevant in Italy).
All outstanding digits are transferred via DTMF.
COMpact 5200/5200R/5500R - Firmware V7.4A - Advanced Information V08 06/2019
port (optional, see Technical Data in the Operating
- 577 -