Settings Alarm
Note: You must select the DDI number to be sent for a PTP
connection from the extensions block. If the DDI number is then displayed
in red text, either it is not in the value range, or the maximum number of
external phone numbers has already been entered.
Note: Alarm calls should preferably be made via the land line.
Délai de temporisation d'alarme 0..99
Specifies how many seconds elapse, after the alarm is triggered on the
switch input, before the first alarm loop starts.
Temps d'attente d'alarme 0..99
Specifies how many seconds elapse before an alarm is repeated, if it has
not been acknowledged.
URL d'action démarrage
The Action URL will be assigned to the alarm type Démarrage alarme.
When an alarm is triggered, the Action URL is sent.
Note: If an alarm delay time was entered, the alarm call via the Action
URL starts after the alarm delay time.
URL d'action confirmation
The Action URL will be assigned to the alarm type Alarme confirmée.
As soon as an alarm subscriber (configured under Devices > Alarms >
Configure > Alarm subscriber (destination number)) acknowlegded the
alarm, the Action URL is sent