Loudspeaker Announcements
Paramètres pour relais analogique
Temps mort
The PBX uses DTMF sequences to control the analogue relays. For this
purpose, the PBX needs to know how much time the connected device
requires to be ready for reception again after receiving DTMF sequences
(see the manual of the device in question).
Requirements:
Created analogue relay
Specifies how many milliseconds the pbx will wait before it sends DTMF
sequences to the connected device again. Possible entries: 0 to 10000
milliseconds.
Commuter
The PBX uses DTMF sequences to control the analogue relays. For this
purpose, the PBX needs to know which DTMF sequences the connected
device requires to switch the relay on or off (see the manual of the device
in question).
Requirements:
Created analogue relay
Activer, Switch off
Enter DTMF sequences required by the connected device. Possible
entries: Digits and the characters * and # and the comma ',' character as a
pause of half a second.