13

13.7 Transmitting Remote Frames

13.7.1 Remote Frame Transmit Procedure

The following describes the procedure for transmitting remote frames.
(1) Initializing the CAN Message Slot Control Register
Initialize the CAN Message Slot Control Register for the slot to be transmitted by writing H'00 to the register.
(2) Confirming that transmission is idle
Read the CAN Message Slot Control Register that has just been initialized and check the TRSTAT (Transmit/
Receive Status) bit to see that transmission/reception has stopped and remains idle. If this bit = "1", it means
that the CAN module is accessing the message slot. Therefore, wait until the bit is cleared to "0".
(3) Setting transmit ID
Set the ID to be transmitted in the message slot.
(4) Setting the Extended ID Register
Set the corresponding bit in the Extended ID Register to "0" if the data is to be transmitted as a standard
frame, or "1" if the data is to be transmitted as an extended frame.
(5) Setting the CAN Message Slot Control Register
Write H'A0 to the CAN Message Slot Control Register to set the TR (Transmit Request) bit and RM (Remote)
bit to "1".
13.7 Transmitting Remote Frames
13-86
CAN MODULE
32180 Group User's Manual (Rev.1.0)