13
CAN0 Slot Interrupt Request Status Register (CAN0SLIST)
CAN1 Slot Interrupt Request Status Register (CAN1SLIST)
b0
1
2
SSB0
SSB1
SSB2
0
0
0
b
Bit Name
0
SSB0 (slot 0 interrupt request status bit)
1
SSB1 (slot 1 interrupt request status bit)
2
SSB2 (slot 2 interrupt request status bit)
3
SSB3 (slot 3 interrupt request status bit)
4
SSB4 (slot 4 interrupt request status bit)
5
SSB5 (slot 5 interrupt request status bit)
6
SSB6 (slot 6 interrupt request status bit)
7
SSB7 (slot 7 interrupt request status bit)
8
SSB8 (slot 8 interrupt request status bit)
9
SSB9 (slot 9 interrupt request status bit)
10
SSB10 (slot 10 interrupt request status bit)
11
SSB11 (slot 11 interrupt request status bit)
12
SSB12 (slot 12 interrupt request status bit)
13
SSB13 (slot 13 interrupt request status bit)
14
SSB14 (slot 14 interrupt request status bit)
15
SSB15 (slot 15 interrupt request status bit)
Note 1: Only writing "0" is effective. Writing "1" has no effect; the bit retains the status it had before the write.
When using CAN interrupts, this register helps to know which slot requested an interrupt.
• Slots set for transmission
The corresponding bit is set to "1" when the CAN module finished sending. This bit is cleared by writing "0" in
software.
• Slots set for reception
The corresponding bit is set to "1" when the CAN module finished receiving and finished storing the received
message in the message slot. This bit is cleared by writing "0" in software.
When writing to the CAN slot interrupt request status, make sure only the bits to be cleared are set to "0" and all
other bits are set to "1". Those bits that have been set to "1" are unaffected by writing in software and retain the
value they had before the write.
Notes: • If the automatic response function is enabled for remote frame receive slots, the request status
is set after the CAN module finished receiving a remote frame and after it finished sending a
data frame.
• For remote frame transmit slots, the request status is set after the CAN module finished sending
a remote frame and after it finished receiving a data frame.
• If the request status is set by an interrupt request at the same time it is cleared in software, the
former has priority so that the request status is set.
3
4
5
6
SSB3
SSB4
SSB5
SSB6
0
0
0
0
13.2 CAN Module Related Registers
7
8
9
10
SSB7
SSB8
SSB9
SSB10
0
0
0
0
Function
0: Interrupt not requested
1: Interrupt requested
13-29
CAN MODULE
<Address: H'0080 100C>
<Address: H'0080 140C>
11
12
13
14
SSB11
SSB12
SSB13
SSB14
0
0
0
0
<After reset: H'0000>
32180 Group User's Manual (Rev.1.0)
b15
SSB15
0
R
W
R(Note 1)