10
10.7.3 TID Control & Prescaler Enable Registers
TID0 Control & Prescaler 3 Enable Register
b8
9
10
TID0M
TID0CEN
0
0
0
b
Bit Name
8–10
TID0M
TID0 operation mode select bit
11
TID0CEN
TID0 count enable bit
12–14
TOU0ENS
TOU0 enable source select bit
15
PRS3EN
Prescaler 3 enable bit
Note: • Operation mode can only be set or changed while the counter is inactive.
The TID0 Control & Prescaler 3 Enable Register is used to select TID0 operation mode (Fixed period count,
Event count, Multiply-by-4 event count or Up/down event count mode), as well as select TOU0_0–7 timer enable
sources and control prescaler 3 startup.
11
12
13
14
TOU0ENS
PRS3EN
0
0
0
0
10.7 TID (Input-Related 16-Bit Timer)
(TID0PRS3EN) <Address: H'0080 07D1>
b15
0
Function
000: Fixed period count mode
001: – ditto–
010: Multiply-by-4 event count mode
011: Event count mode
100: Fixed period count mode
101: – ditto –
110: Multiply-by-4 event count mode
111: Up/down event count mode
0: Stop TID0 count
1: Start TID0 count
000: Disable event enable
001: – ditto –
010: TID0 underflow/overflow
011: TOU0_7 underflow
100: Disable event enable
101: – ditto –
110: Output event bus 0
111: External input TIN25 signal
0: Stop count
1: Start count
10-141
MULTIJUNCTION TIMERS