G.8032 E
R
P
THERNET
ING
ROTECTION
8032
-
G
PHYSICAL
RING

g8032 physical-ring

Overview
Use this command to create a G.8032 Ethernet Ring Protection (ERP) physical ring
profile which specifies the Ethernet ports that will be used as G.8032 ring ports.
g8032 physical-ring <physical-ring-name> {east-interface
Syntax
<interface-name1> west-interface <interface-name2>|
terminating-interface <interface-name>}
no g8032 physical-ring <physical-ring-name>
Mode
Global Configuration
Usage notes
Each ERP instance will be associated with a physical ring profile. A physical ring
profile is made up of two physical Ethernet ports or aggregated interfaces, unless
it is the terminating point of a sub-ring in which case only one port is needed.
When two ports are used, they are referred to as East and West ports. When only a
single port is used, it is referred to as a Terminating port.
Example
To create a physical ring profile named "red" where the East interface port is
port1.0.4 and the West interface port is port1.0.8, use the following commands:
awplus#
awplus(config)#
port1.0.4 west-interface port1.0.8
Related
physical-ring
commands
rpl role
show g8032 physical-ring
C613-50644-01 Rev B
S
C
WITCHING
OMMANDS
Parameter
<physical
-ring-name>
east-interface
<interface-name1> The name of the switch interface, either port or channel
west-interface
<interface-name2> The name of the switch interface, either port or channel
terminating
-interface
<interface-name>
configure terminal
g8032 physical-ring red east-interface
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
The name of the profile (up to 37 characters)
The East G.8032 ring port
group, for the East ring port. It must differ from the West ring
port.
The West G.8032 ring port
group, for the West ring port. It must differ from the East ring
port.
The Terminating ring port. This should only be used for
G.8032 ERP instance that is at the end of a sub-ring.
The name of the switch interface, either port or channel
group, for the Terminating ring port.