Lldp Reinit - Allied Telesis x510-28GTX Command Reference Manual

Stackable gigabit edge switches x510 series
Table of Contents

Advertisement

LLDP C
OMMANDS

LLDP REINIT

lldp reinit
Overview
This command sets the value of the reinitialization delay. This is the minimum time
after disabling LLDP on a port before it can reinitialize.
The no variant of this command sets the reinitialization delay back to its default
setting.
Syntax
lldp reinit <1-10>
no lldp reinit
Default
The default reinitialization delay is 2 seconds.
Mode
Global Configuration
Examples
To set the reinitialization delay to 3 seconds, use the commands:
awplus#
awplus(config)#
To set the reinitialization delay back to its default, use the commands:
awplus#
awplus(config)#
Related
show lldp
Commands
C613-50170-01 Rev B
Parameter
Description
<1-10>
The delay in seconds.
configure terminal
lldp reinit 3
configure terminal
no lldp reinit
Command Reference for x510 Series
AlliedWare Plus™ Operating System - Version 5.4.7-1.x