Atmf Management Subnet - Allied Telesis x510-28GTX Command Reference Manual

Stackable gigabit edge switches x510 series
Table of Contents

Advertisement

A
T
M
F
LLIED
ELESIS
ANAGEMENT

ATMF MANAGEMENT SUBNET

atmf management subnet
Overview
This command is used to assign a subnet that will be allocated to the AMF
management and domain management VLANs. From the address space defined
by this command, two subnets are created, a management subnet component
and a domain component, as explained in the Usage section below.
AMF uses these internal IPv4 subnets to communicate network status information
between nodes. These subnet addresses must be reserved for AMF and not used
for other purposes.
CAUTION
management VLAN, and management subnet.
CAUTION
subnet of a node, that change takes effect immediately and the node will immediately
leave the AMF network and try to rejoin it. The AMF network will not be complete until
you have given all devices the same setting, so they can all rejoin the AMF network.
Use the no variant of this command to remove the assigned subnet.
Syntax
atmf management subnet <a.b.0.0>
no atmf management subnet
Default
172.31.0.0. A subnet mask of 255.255.0.0 will automatically be applied.
Mode
Global Configuration
Usage
Running this command will result in the creation of a further two subnets (within
the class B address space assigned) and the mask will extend from /16 to /17.
For example, if the management subnet is assigned the address 172.31.0.0/16, this
will result in the automatic creation of the following two subnets:
We recommend you only change the management subnet when first creating the
AMF network, and only if 172.31.0.0 is already being used in your network.
C613-50170-01 Rev B
™ (AMF) C
RAMEWORK
OMMANDS
: Every member of your AMF network must have the same domain VLAN,
: If you change the domain VLAN, management VLAN, or management
Parameter
Description
<a.b.0.0>
The IP address selected for the management subnet. Because a
mask of 255.255.0.0 (i.e. /16) will be applied automatically, an IP
address in the format a.b.0.0 must be selected.
Usually this subnet address is selected from an appropriate
range from within the private address space of 172.16.0.0 to
172.31.255.255, or 192.168.0.0, as defined in RFC1918.
172.31.0.0/17 assigned to the
172.31.128.0/17 assigned to the
Command Reference for x510 Series
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
atmf management vlan
atmf domain
vlan.
2267

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents