Migrating a DEFINITY Server R to an S8700-Series Media Server
Checking the link status
Compare the list that you made before the migration. Ensure that the in-service or the
out-of-service links match the status of the links before the migration.
To check the link status:
1. Type display communication-interface links. Press Enter.
2. Record all the enabled links.
3. Type status link number where number is a number 1-99. Press Enter.
4. Compare which links are in service with the premigration list.
5. Repeat steps 3 and 4 for all link numbers.
Upgrading firmware
Each IPSI must be on the most current and same firmware load. You might need to upgrade the
firmware on the IPSI. The most current firmware load is on the installation CD. To obtain the
firmware, you also can go to Avaya Support Web
Downloads.
First, verify the version of firmware that is currently on the IPSI circuit pack.
1. Under Installation and Upgrades, click View IPSI Version. Select Query All and click View
IPSI Version.
2. Verify the firmware release for the TN2312BP IPSI.
If necessary, upgrade the firmware on the just installed TN2313BP IP Server Interface circuit
pack that you just installed. For more information, see
SIPIs
on page 283.
You also must upgrade the firmware on the following circuit packs, if necessary.
UDS1 (TN464GP, TN2464BP, and TN2313AP)
Maintenance/Test (TN771DP)
Control LAN (CLAN) (TN799DP)
IP Media Processor (TN2302AP)
For more information, see
796 Upgrading, Migrating, and Converting Media Servers and Gateways
Upgrading firmware on the IPSIs and SIPIs
page(http://avaya.com/support
Upgrading firmware on the IPSIs and
on page 283.