Advertisement

5. At the SAT, enter change circuit-pack.
a. Type blanks in the EI fields (TN570) for the PNs that you are converting to IP-PNC.
b. Type blanks the ATM-EI fields (TN2305/6) for the PNs that you are converting to IP-PNC.
c. Type blanks the corresponding Tone Clock (TN2182) fields.
d. Press Submit.
6. If converting all PNs to IP-PNC, remove the ATM switch.
Administering PN synchronization, if necessary
Perform this procedure if the PN that you just converted to IP-PNC requires a synchronization
source. To administer synchronization:
1. After the conversion, enter the SAT commands list synchronization and status
synchronization to show the synchronization information for the IP-PNC PNs. The
Primary and the Secondary fields on the Synchronization Plan screen and the Source
Physical Location field on the Synchronization Status screen must be empty.
2. Enter change synchronization port-network n, where n is the PN number of the
converted port network that requires synchronization.
Tip:
Enter list cabinet to see a list of all the cabinets and the PNs that the
Tip:
cabinets contain.
Conversion Tasks
Issue 2.1 June 2006
1135