Migrating from an S8700 Media Server to an S8710 Media Server
Premigration setup
Note:
The premigration team must have completed the following tasks. If these tasks
Note:
were not completed, do not continue with the migration.
When you are migrating from a DEFINITY system, complete the following additional tasks
before starting the migration:
Task
Remove all Mode II Data
Modules before you change
the S8710 Media Server.
On the IP Services screen
in the Service Type field,
remove Alarm1 and
Alarm2.
On the Trunk Group
screen, change the
Measured field from
measured to none.
Check the Dial Plan screen
(or Dial Plan Analysis
Table screen depending on
the release) for 0 assigned
as attd.
894 Upgrading, Migrating, and Converting Media Servers and Gateways
Description
The S8710 does not support the following data
modules:
System Ports
●
PDMs (7400/8400 Data Modules)
●
PktGateway
●
Pkt Data Dataline
●
Modem Pool
●
System CDR PDMs
●
System Features Printer PDMs
●
You first might need to change the System
Parameters Maintenance screen before you can
make any changes to the IP Services screen.
This action indicates that trunk group measurement
reports are not required. Remember to remeasure
trunk groups.
To get a list of trunk groups that are "measured" and
need to be changed, type list trunk-group.
If there are none, check the Attendant Console
screens for any buttons with attd-qcalls or attd-qtime
btns. Remove these if 0 is not assigned as attd.
1 of 2