Resolving alarms
To clear alarms:
1. Under Alarms, click Current Alarms to examine the alarm log.
2. Select the server alarms that you want to clear and click Clear, or click Clear All.
3. Resolve or clear Communication Manager alarms with SAT commands and the
Maintenance Commands Reference and Alarms Maintenance books.
Checking for translation corruption
To check for translation corruption:
1. Type newterm. Press Enter.
2. If you see the following message:
Warning: Translation corruption detected . . .
then follow the normal escalation procedure for translation corruption before continuing the
upgrade.
Disabling scheduled maintenance
The following steps prevent scheduled daily maintenance from interfering with the conversion.
1. On the SAT, enter change system-parameters maintenance.
2. If scheduled maintenance is in progress, set the Stop Time field to 1 minute after the
current time.
or
If scheduled maintenance is not in progress, set the Start Time field to a time after the
conversion will be completed.
For example, if you start the conversion at 8:00 P.M. and it takes 4 hours, set the Start Time
field to 23:59.
Prerequisites
Issue 2.1 June 2006
1083