Avaya S8100 Series Manual page 1087

Media servers and gateways
Hide thumbs Also See for S8100 Series:
Table of Contents

Advertisement

4. Verify that the synchronization sources are updated correctly:
5. Perform one of the following actions:
If you are converting all PNs to IP-PNC and have blanked out the Primary and
Secondary fields, enter list synchronization. Verify that the Primary and
Secondary fields for CSS are blank. Then skip to
page 1088.
If some PNs remain fiber-connected, complete the following steps:
a. Enter list synchronization.
b. On the Synchronization Plan screen, note the Primary and the Secondary locations
for CSS.
c. Enter status synchronization.
d. On the Synchronization Status screen, the Source Physical Location field for CSS
must show the same location that is listed as Primary on the Synchronization Plan
screen. In this example, the location is 02B07. If the screen shows that the CSS uses
the secondary synchronization source or the tone-board as the synchronization
source, follow the troubleshooting guide for synchronization sources.
Conversion Tasks
Adding new circuit packs
Issue 2.1 June 2006