You have the most recent firmware for duplicated TN2602AP circuit packs. You may need
to upgrade the firmware on the circuit packs if you find that they don't have the most recent
and appropriate firmware.
Note:
Non-duplicated TN2602AP firmware is different from duplicated TN2602AP
Note:
firmware. Be sure the firmware you have is for duplicated TN2602AP circuit
packs.
In each IP-PNC PN that has both duplicated control and duplicated bearer, a TN771DP
maintenance test circuit pack must be installed.
You have completed the pre-site checklist,
the customer site.
Unless one of the following conditions exists, you will need IP addresses, node names,
and slots for the TN2602AP IP Media Resource 320 circuit packs:
- You are replacing TN2302 circuit packs with the TN2602AP circuit packs and therefore
are not reusing the TN2302 IP addresses, node names, and slots.
- You are reusing load-balanced TN2602AP circuit packs that are already installed in
the port network.
You may also need the subnet mask and the default gateway IP address.
Note:
Get this information from the project manager or the customer's network
Note:
administrator.
The Communication Manager software on S8700-series Media Servers must be upgraded
to release 3.1 or later.
The Communication Manager license file must have at least two entries, either
VALUE_2602_80VC or VALUE_2602_320VC, with the same number of VoIP channels -
either both 80 or both 320.
(Optional) You may need to install a second Ethernet switch, if necessary, for connections
to the network for the duplicated TN2602AP circuit packs. Adding a second Ethernet
switch adds reliability to the duplicated bearer network. That is, if the failure is at the
Ethernet switch or its connection to the TN2602AP circuit pack, the standby TN2602AP
circuit pack can handle traffic through the alternate Ethernet switch.
If there are already two Ethernet switches for duplicated control and the Ethernet switches
are also connected to the customer LAN, you do not need a second Ethernet switch.
(Optional) If you install a second Ethernet switch, you may need to install a second UPS to
support the second Ethernet switch, if necessary.