Converting simplex bearer to duplicated bearer on IP-PNC port networks (with S8700-series Media Servers
Administering the IP interface for the TN2602AP circuit packs
To administer the IP interface for the circuit packs, perform the following steps on the circuit
pack you want to be the active circuit pack:
Note:
Any calls active when you start this procedure continue to use the TN2602AP
Note:
circuit pack's physical IP address for the connection, not the virtual IP address
you are setting in this procedure. Therefore, any of these calls, if they continue
after you complete this procedure, will drop in the event of an interchange.
1. Type one of the following commands:
For a previously-existing TN2602AP circuit pack that is still administered, type change
ip-interface UUCSS and press Enter, where UUCSS is the cabinet, carrier, and slot
location.
For a newly-installed TN2602AP circuit pack that you are administering as the active
circuit pack, type add ip-interface UUCSS, and press Enter
The IP Interfaces screen appears.
add ip-interface 1a03
Enable Ethernet Port? y
1214 Upgrading, Migrating, and Converting Media Servers and Gateways
Critical Reliable Bearer? n
Type: MEDPRO
Slot: 01A03
Code/Suffix: TN2602
Node Name: medres03a01
IP Address: 192.168.1.82
Subnet Mask: 255.255.255.0
Gateway Address: . . .
Network Region: 1
VLAN: n
Auto? n
Speed: 100 Mbps
Duplex: Full
IP INTERFACES
ETHERNET OPTIONS
Page 1 of 1