Enter set vlan tag on
●
Enter set port negotiation 1 disable
●
Enter set port duplex 1 full
●
Enter set port speed 1 100
●
4. Enter show qos to check the administered values.
5. Enter quit to exit.
!
Important:
Ensure that the port settings on the Ethernet switches are set to the same values
Important:
as in the set port commands.
6. Telnet to the IPSI and log in.
7. Enter reset.
Enter y in response to the warning.
8. Disconnect the laptop from the IPSI.
9. Verify that the LED display on the IPSI faceplate contains I P and a filled-in "V" at the
bottom.
Starting a SAT session
To start a SAT session:
1. Start a terminal emulation application, such as Native Configuration Manager or Microsoft
HyperTerminal or use a telnet session.
2. Type telnet 192.11.13.6 5023. Press Enter.
3. Log on as craft or dadmin.
4. Suppress alarm origination.
Administering the duplicated IPSI circuit pack on the media server
To administer the TN2312BP circuit pack on the media server:
Note:
Steps 1 needs to be completed just once for all IPSIs. Step 2 must be repeated
Note:
for each duplicated IPSI you are adding.
1. On the SAT command line interface, enter change system-parameters duplication
and set Enable Operation of IPSI Duplication to y.
2. Enter add ipserver-interface n, where n is the PN number, to add the new IPSI.
Procedure
Issue 2.1 June 2006
1199