Performing an integrity check on the active S8720 Media Server
To perform an integrity check on the active S8720 Media Server:
1. On the Maintenance Web Interface, under Diagnostics, click Server > Status Summary.
The system displays the Status Summary window.
2. Verify the following:
Mode: Active
Server Hardware: okay
Processes: okay
3. Select Server > Process Status.
The system displays the Process Status window.
4. Under Frequency, click Display Once.
5. Click View.
6. Verify all operations are Up except ENV can be off.
Upgrading H.248 media gateways, LSPs, and ESSs (if being used)
If newer firmware exists for a configuration using H.248 media gateways, LSPs, or ESSs, and
media modules, you must upgrade the firmware on them first. If the media server is the primary
controller for a G700 Media Gateway equipped with an LSP or ESS, you must upgrade the
software on the LSPs or ESSs before the migration. The correct order is:
1. Upgrade media gateway firmware to latest version
2. Upgrade media modules firmware to latest version
3. Upgrade media server software to latest version if using LSPs
4. Migrate to the S8720 Media Server.
Interchanging media servers (optional)