Converting simplex bearer to duplicated bearer on IP-PNC port networks (with S8700-series Media Servers
Connecting the cables to any new TN2602AP circuit packs
You need to cable any new TN2602AP circuit packs you are installing in the port network.
To install the cable for an IP Media Resource 320 circuit pack, perform the following steps:
Note:
If installing the TN2602AP into an old carrier or cabinet, you must replace the WP
Note:
cables, which connect the backplane to the rear connector panel, with Twisted
Pair I/O cables to handle the 100 Mbps speed. See
page 1219 for information on replacing the wires.
1. From the rear of the media gateway, connect the amphenol connector on the adapter to the
amphenol connector corresponding to each TN2602AP slot. See
Resource 320
Figure 100: Media Resource 320 Adapter
Figure notes:
1. Amphenol connector to
backplane connector
corresponding to TN2602AP slot
2. RS-232 connector for services
!
Important:
Plug the CAT5 cable into the top port labeled Port 1. Do not plug it into the
Important:
second port.
2. Connect the network cable(s) to the Port 1 ETHERNET connector on the Media Resource
320 adapter(s) on the backplane.
3. Snap the retainer clip(s) over the adapter(s) to hold them in place.
1210 Upgrading, Migrating, and Converting Media Servers and Gateways
Adapter.
2
addf2602 LAO 112105
Replacing the I/O cables
3
1
3. Port 1: RJ45 LAN cable connection for
100 Mbps CAT5 cable
4. Port 2: RJ45 LAN connection for