Task
16. Verify LSP status.
17. If the LSP's translations
have not synchronized
with the primary
controller, invoke
translation
synchronization.
18. Implement any additional
design changes to voice
and/or voice messaging
networks.
19. Re-register the S8300 as
an LSP with the Avaya
remote servicing center.
On the LSP's primary controller
At the SAT prompt, enter list
●
survivable-processor (for CM R3.1) or list
lsp (for CM R2.x). The LSP name and IP address
should be listed.
The Translations Updated date and time should
●
match the translations date and time on the primary
controller. To view the primary controller's
translations dates and times, enter list
configuration software-version.
On the primary controller, enter the Linux
●
command filesync -a ipaddress
where ipaddress is the IP address of the LSP.
Ensure that the translation synchronization
●
completed successfully. Wait several minutes, then
check the timestamp of the LSP translation files
using the SAT command list
survivable-processor or list lsp on the
primary controller.
Post-conversion tasks
Steps/Comments
Issue 2.1 June 2006
Introduction
5 of 5
1163