To release alarm suppression:
1. Access the command line interface of the server with an SSH client like PuTTY and an IP
address of 192.11.13.6.
2. Log in as craft or dadmin.
3. Type almsuppress -n and press Enter to release alarm suppression.
4. Log off.
Logging off all administration applications
When you complete all the administration, log off all the applications that you used.
Configuration Diagrams
Figure 80: A fiber-PNC configuration for an S8700-series CSS with duplicated control
networks
on page 1106 and
S8700-series with mixed reliability — converted from CSS configuration
diagrams for the conversion of a CSS system from a fiber-PNC configuration to a mixed
fiber-PNC and IP-PNC configuration. In this configuration, PNs <8> and <19> are converted
from fiber-PNC to IP-PNC. The other PNs remain fiber-connected through the CSS.
Figure 82: Example of MCC1 Media Gateway with IP-PNC and mixed reliability
shows a typical MCC1 gateway that is converted to IP-PNC with three IP-PNC PNs.This
diagram is an example of an MCC1 with three IP-PNC PNs, one of which has a duplicated
control network. The MCC1 is remote from the media servers and, thus, requires a second set
of Ethernet switches.