Avaya S8100 Series Manual page 1109

Media servers and gateways
Hide thumbs Also See for S8100 Series:
Table of Contents

Advertisement

Figure notes: Mixed fiber-PNC and IP-PNC configuration for S8700-series with mixed
reliability (converted from CSS configuration)
1.
S8700 or S8710 Media Server
2.
Ethernet Switch.
3.
MCC1 Media Gateway (CSS and PN)
4.
PN control carrier, in the A position that contains:
A TN2312AP/BP IPSI circuit pack for IP connection to server.
A TN570 EI circuit pack for bearer and control network connections to the switch node carrier (SNC).
5.
Duplicated control carrier in the B position that contains a TN2312AP/BP IPSI circuit pack for IP connection to duplicated
control network.
6.
SNC in the E position that contains multiple TN573B SNI circuit packs for EI connections to PNs.
7.
Dedicated IPSI-to-server control network connection through the Ethernet switch.
8.
IP-PNC PN with duplicated control networks (G650 Media Gateway stack, MCC1 Media Gateway, or SCC1 Media Gateway
stack, consisting of at least two media gateways or carriers). The figure shows a G650 stack.
9.
PN control gateway or carrier in the A position that contains a TN2312AP/BP IPSI circuit pack for IP connection to server.
NOTE: For the G650 Media Gateway, the BP version of the TN2312 is required in order to provide environmental
maintenance.
10.
Duplicated control gateway, in the B position that contains a TN2312AP/BP IPSI circuit pack for IP connection to server.
11.
Fiber-PNC PN (G650 Media Gateway stack, MCC1 Media Gateway, or SCC1 Media Gateway stack), consisting of at least
two media gateways or carriers. The figure shows a G650 stack and an SCC1 stack.
12.
PN control gateway or carrier in the A position that contains a TN570 EI circuit pack for bearer and control network
connections to the SNI.
NOTE: One TN2182 Tone Clock circuit pack must also be present per PN if the PNs consist of SCC1 or MCC1 Media
Gateways. One maintenance-only TN2312BP IPSI circuit pack must be present per PN if the PNs consist of G650
Media Gateways.
13.
TN 570/573 fiber connections between the PNs and the SNC
14.
TN 573B/570 fiber connections between the SNC and the A carrier of the MCC1, if the MCC1 is a PN
15.
Customer LAN
16.
LAN connections of TN2302AP IP Media Processor or a TN2602AP IP Media Resource 320 for voice processing, and
optional TN799DP C-LAN for control of IP endpoints. The TN2302AP and/or TN2602AP media processor circuit packs are
required for the IP-PNC PNs and optional for the fiber-PNC PNs.
NOTE: The number of TN2302AP, TN2602AP, and TN799DP circuit packs varies, depending on the number of IP
endpoints, PNs, and adjunct systems. These circuit packs can be inserted into a port carrier, as shown in figure, the
PN control carrier, or the duplicated control carrier. However, the CLAN circuit pack is required for downloads of
firmware updates.
17.
LAN connections of media servers for remote administration.
18.
Duplicated server links, including the link for translations transfer and the link for control data sharing.
19.
IP-PNC PN with a single control network (G650 Media Gateway stack, MCC1 Media Gateway, or SCC1 Media Gateway
stack, that consists of at least two media gateways or carriers). The figure shows a G650 stack.
Configuration Diagrams
Issue 2.1 June 2006
1109